 |
| Product Catalog |
 |
Access Control & All-in-One Card Systems |
 |
| |
|
 |
Automatic doors ¨C sensor doors- Revolving Door |
 |
| |
|
 |
Door hardware and partitions |
 |
| |
|
 |
Sensor doors - electric doors - glass doors - sliding doors |
 |
| |
|
| |
| Brand Recommendations |
| |
|
 |
| |
| Contact Phone |
| +86 21 68568185 68567085 |
| Beijing, Shanghai, Guangzhou, Shenzhen |
| Fax |
| +86 21 68567085 |
|
|
| Product Inquiry Technical Service |
 |
| Automatic door repair & sensor door maintenance in Shanghai - official website www.zitin.com.cn www.shanghai-door.com |
| DORMA automatic doors, door closers, floor springs - www.zitin.com.cn/dorma DORMA sensor door repair & maintenance official website www.shanghai-door.com/dorma |
| GEZE automatic doors, door closers, floor springs: www.zitin.com.cn/geze official website for GEZE sensor door repair & maintenance: www.shanghai-door.com/geze |
| Hangzhou, Suzhou, Nanjing, Chengdu, Chongqing, Wuhan, Xi'an, Tianjin, Changsha, Foshan, Xiamen, Fuzhou |
| Zhengzhou, Dongguan, Qingdao, Jinan, Shenyang, Kunming, Ningbo, Wuxi, Changzhou, Hefei, Dalian |
| Service center for the design, installation, repair, maintenance and upkeep of Shanghai sensor doors, electric doors, glass doors and sliding doors. Products are used in shopping malls, supermarkets, banks, shops, retail stores, automotive facilities, hospitals, office towers, residential communities, data centers, factories and more. |
 |
|
|
Current location: Home>Products > Access Control & All-in-One Card Systems > Water & Electricity Control Systems >
Xikalong Water Control Management System |
Beijing, Shanghai, Guangzhou, Shenzhen, Hangzhou, Suzhou, Nanjing, Chengdu, Chongqing, Wuhan, Xi'an, Tianjin, Changsha, Foshan, Xiamen, Fuzhou, Zhengzhou, Dongguan, Qingdao, Jinan, Shenyang, Kunming, Ningbo, Wuxi, Changzhou, Hefei, Dalian Price |
Xikalong Water Control Management System |
|
|
|
Water Control Management System Fully waterproof design with a double-layer joint between the upper and lower shells and silicone seals for waterproofing; it adopts a ** infrared-sense button design, eliminating mechanical buttons for a simpler appearance, better waterproofing and easier use; a ** water-saving design uses both card-reading and switch to control water: water flows after card insertion, and stops when the card is removed or via infrared sensing, making it ** user-friendly and water-saving; a ** power-saving design automatically cuts power after 30 minutes with no card read or button operation, and automatically restarts on card read or button press; billing by timed metering, which is ** scientific, fair and reasonable; the 680 model uses an e-wallet method, recording only the amount spent, eliminating the hassle of account reconciliation, and a collection card can be used to extract cumulative consumption data without complex networking, reducing construction work; the W690 model records detailed consumption for customer queries and account reconciliation; the system is easy to install, and the host software can be integrated with the existing consumption management system, directly issuing cards without re-entering personnel information, making it easy to extend the existing consumption system into a card-based all-in-one system; user top-up is simple and convenient, available via either a transfer machine for on-card transfer or a management center top-up.
IC Card Water Control Main Unit
Product model:RF690

*Card type read: MIFARE card, ID card *Card reading time: <0.3 seconds *Sensing distance: 25¡«**mm (card can be left in place) *Card issuance capacity: 680 model unlimited, 690 model over 1,000,000 *Max record volume: 690 model £¤9,990,000, 890 model 10,000 records *Data storage: FLASH saves data, retained on power loss *Billing precision: £¤0.01 Display: 6-digit digital tube display *Operating voltage: DC12V, power consumption <3W Weight: 380g *Dimensions: 139mm x 120mm x 28mm
Electricity Management System IC Card The Xikalong series intelligent energy metering system is a high-tech energy metering management system that combines an intelligent electricity meter with a microcomputer control unit and connects to a computer. It integrates energy metering, time-period control, load control, real-time monitoring and many other functions, facilitating **ized meter management while preventing various phenomena such as electricity theft, leakage and overload. It can automatically read, archive and settle electricity consumption, ensuring data accuracy, and can warn, cut power and restore power for users in arrears, saving a great deal of manual meter-reading time. It is especially suitable for modern university dormitory management and residential apartment management.
¡ñ Uses advanced imported energy-metering chips, ensuring high metering accuracy and reliability
¡ñ Real-time computer networking enables convenient charging, eliminating the hassle of manual meter reading and billing.
¡ñ Thoughtful time-period functions, convenient for school management and student use.
¡ñ Fully automatic load control function, ensuring student electricity safety.
¡ñ Real-time computer monitoring function, giving you freer operation.

System Composition: The system consists of system software, network, data manager and power-control cabinet.
Introduction to System Components:
*System software: uses multi-threaded distributed technology and supports multiple online modes to better meet users' varied needs. It is simple to install and easy to use, can manage 256 data managers, and features energy metering, monitoring of power use, charging management, and statistical query of various data. It can monitor the power use of each branch unit in real time, and supports report query and printing by day, week, month, quarter and year. *Network: can use RS485 or the TCP/IP protocol over the campus network; when networked, the computer directly transmits data to, manages and controls the power units without using IC cards for data transfer. *Data manager: LCD display, Chinese menu. Manages the lower units and provides query functions for various room data. Works directly in place of the computer when offline. *Power-control cabinet: comes in two types, **ized cabinets and floor-by-floor embedded cabinets. The **ized cabinet is placed in the mailroom or electrical room of the dormitory; the floor-by-floor embedded cabinet is mounted on the corridor wall of each floor of the dormitory building, metering, managing and controlling the power of each room. Each **ized cabinet manages up to 140 rooms, and each embedded cabinet manages up to 32 rooms.
The Xikalong series intelligent **ized energy metering system was **ed for student collective apartments with the goal of providing a complete application solution. Its basic starting point is systematic functional combination and effective **ized management: systematic functional combination is a necessary prerequisite for a dedicated system, and effective management is mainly to better suit the use, installation environment and future **ment of student collective apartments. The on-site system can use either a **ized cabinet or a floor-by-floor cabinet system as needed; the power-purchase system consists of a computer with power-purchase software installed and a card reader.
This system integrates energy calculation, load control, dual protection, charging management and statistical analysis of power-use data, eliminating meter reading and electricity-fee collection. Suited to the characteristics of collective apartments, it effectively prevents cable theft and equipment damage, and can ** management through statistical analysis of power-use data. It uses card technology for prepayment, realizing the modern consumption model of "pay first, consume later" for users. It has low self-power-consumption, and the per-branch power consumption is far lower than ordinary watt-hour meters.
Main Functions:
*Supports two-wire control per branch: can cut/restore power for each user in two circuits (one for lighting and sockets, one for fans). *Can individually set the maximum power use per household: within the limits allowed by the system, the school can individually set the maximum load for each user via the system software; each user can have a different load value. When this value is exceeded, the system automatically cuts power to that user without manual switch-on, and the system automatically restores power; only when several detections all exceed the set maximum load will it cut power **, and the system automatically records one overload for that user. This both avoids the hassle of students needing to find duty staff to restore power after mistakenly plugging in an appliance, and prevents the use of unsafe appliances, making management easy - a truly humanized design. **Intelligent load recognition: the system can recognize loads by their inductive or resistive characteristics, thereby effectively controlling the use of high-power resistive loads. This both makes it easier for the school to manage illegal appliances such as electric stoves and avoids fire hazards, without affecting students' use of normal appliances such as computers. **Can schedule power on/off for all users: in the system software, the week is divided into seven days and each day into four time periods; the school can freely set different power on/off times each day according to its actual situation, and the system executes automatically once set. **Can individually cut/restore power for a specific user: in the system software this is done by a mouse click, safely and reliably; it can also be done on the manager by entering the room number to cut/restore and then entering the corresponding command. **Powerful automatic power-off for arrears: besides the simple function of automatically cutting power when electricity runs out, the school can set various conditions via the system software. For example, it can allow a few extra kWh after the fee runs out, avoiding the hassle of power running out at night after staff have left and the fee cannot be paid; in addition, it can allow each user a few free kWh per month and charge beyond that, etc. As for the price per kWh, the school can freely set it according to its situation, facilitating school management. **Real-time user status indication: the control cabinet panel has various indicator states, each lamp corresponding to one user. Lamp off means power cut; ** means normal supply; red means that user is overloaded or on a resistive load; flashing ** means power is below the minimum and the user should buy power as soon as possible. Both managers and students can see the power status at a glance. **Convenient payment management: after a student pays, the amount can be entered directly into the system via the system software; the system saves it automatically and can print the receipt directly. This both relieves students of the burden of buying magnetic cards and avoids the trouble of lost or damaged cards. **Convenient query functions: the system software supports various queries: basic information of each room (room number, dorm leader, phone number, etc.); each user's current-month power use (monthly consumption, amount paid, balance, etc.); last month's power use (same content); the list of illegal use among all users (overloaded room numbers, number of overloads); and current arrears (room numbers in arrears, amounts owed, etc.), all facilitating management. *Reliable data security: the system has a powerful database that saves each user's monthly power use for 4 years and daily power use for 2 months, with a backup function for regular backups to ensure safety. Even in an unexpected situation, the control cabinet retains each user's 2-month power data, and recovery only requires re-reading the meters. Meanwhile, the control cabinet's memory uses flash storage, so internal data is retained during power cuts. **Multi-level password protection: from the viewpoint of usage security, the system sets level-1 and level-2 passwords, each with different privileges; different managers can modify system parameters according to the privilege level of the password given to them, while those without a password can only query and cannot change system parameters, ensuring usage security. **Protection for the power path: the system equips each user with a miniature circuit breaker for short-circuit protection, and can add earth-leakage protection, over-voltage protection and other devices as needed. *Emergency handling: if the system malfunctions, a switch can cut off the control system and restore the power path, so that even when a fault occasionally occurs, students' power use is not affected.
Technical Specifications: *System input power: three-phase 380V **Hz *Per-branch user output power: single-phase 220V **Hz *Per-branch max current load: 10A-40A (optional) *Per-branch short-circuit protection value: 10A, 1**, 20A, 30A, 40A (optional) *Per-branch power consumption: ¡Ü1W *Operating ambient temperature: -10¡æ-£«**¡æ *Metering accuracy: Class 1.0 *Creep: anti-creep *Max stored energy value: 15,000 kWh *Data storage validity: 10 years *Safety: meets civil low-voltage distribution equipment requirements *Reliability: the product withstands power transient pulse interference and operates normally *Housing insulation resistance: ¡Ý5M *The network version of the SIMS energy metering management system. Through the school's LAN, it can transmit the power-use information of the entire campus to the school's power management center; the monitoring computers of each management area can be placed in their respective management rooms, facilitating layer-by-layer school management. Students can use a card to query their own power use, or enter a room number to query.
Technical Parameters:
Model On-site installation dimensions (L x W x H, unit: mm) Cabinet dimensions (unit: mm) CFD-J-48/64 **0 X ** X 1210 **0 X ** X 1210 CFD-J-80 **0 X ** X 1410 **0 X ** X 1410 CFD-J-96 **0 X ** X 1610 **0 X ** X 1610 CFD-J-112 **0 X ** X 1810 **0 X ** X 1810
|
|
|