| Product Catalog |
 |
Access Control & All-in-One Card Systems |
 |
| |
|
 |
Automatic doors ¨C sensor doors- Revolving Door |
 |
| |
|
 |
Door hardware and partitions |
 |
| |
|
 |
Sensor doors - electric doors - glass doors - sliding doors |
 |
| |
|
| |
| Brand Recommendations |
| |
|
 |
| |
| Contact Phone |
| +86 21 68568185 68567085 |
| Beijing, Shanghai, Guangzhou, Shenzhen |
| Fax |
| +86 21 68567085 |
|
|
| Product Inquiry Technical Service |
 |
| Automatic door repair & sensor door maintenance in Shanghai - official website www.zitin.com.cn www.shanghai-door.com |
| DORMA automatic doors, door closers, floor springs - www.zitin.com.cn/dorma DORMA sensor door repair & maintenance official website www.shanghai-door.com/dorma |
| GEZE automatic doors, door closers, floor springs: www.zitin.com.cn/geze official website for GEZE sensor door repair & maintenance: www.shanghai-door.com/geze |
| Hangzhou, Suzhou, Nanjing, Chengdu, Chongqing, Wuhan, Xi'an, Tianjin, Changsha, Foshan, Xiamen, Fuzhou |
| Zhengzhou, Dongguan, Qingdao, Jinan, Shenyang, Kunming, Ningbo, Wuxi, Changzhou, Hefei, Dalian |
| Service center for the design, installation, repair, maintenance and upkeep of Shanghai sensor doors, electric doors, glass doors and sliding doors. Products are used in shopping malls, supermarkets, banks, shops, retail stores, automotive facilities, hospitals, office towers, residential communities, data centers, factories and more. |
 |
|
|
Current location: Home>Products > Access Control & All-in-One Card Systems > Access Control & Attendance Systems >
SIEMENS Access Control -SRI Single Card Reader Module |
Beijing, Shanghai, Guangzhou, Shenzhen, Hangzhou, Suzhou, Nanjing, Chengdu, Chongqing, Wuhan, Xi'an, Tianjin, Changsha, Foshan, Xiamen, Fuzhou, Zhengzhou, Dongguan, Qingdao, Jinan, Shenyang, Kunming, Ningbo, Wuxi, Changzhou, Hefei, Dalian Price |
SIEMENS Access Control -SRI Single Card Reader Module |
SIEMENS Access Control -SRI Single Card Reader ModuleInstallation manual, video, repair and maintenance service center prices |
| |
|
|
|
Siemens Access Control - SRI Single Reader Module Shanghai Zitin Exclusive Store +86 21 68568185 www.zitin.com/siemens
Product Description
SiPass Integrated Single Reader Interface (SRI)
Secure control of a single door is the top priority of any good access control system. Between the system and its components, field-level devices provide an interface that must ensure the access control is reliable, flexible and easy to install. The Single Reader Interface Module (SRI) offers all of these advantages.
The SRI provides an on-site interface between the Advanced Central Controller (ACC) and a card reader. This allows the SRI to receive the cardholder¡¯s identity information when requesting entry to a locked door, and then send that identity data to the ACC for verification. In addition, the SRI can report the door status and, on command, unlock or lock the door. When a cardholder presents an access card at the reader (connected to an SRI), the SRI interprets the encoded information and sends the data to the ACC. The ACC then checks the cardholder¡¯s validity. If the cardholder has the appropriate permission, the ACC sends a command back to the SRI: unlock the door and allow passage.
We designed the SRI carefully so that it can be easily installed at any suitable location. This includes convenient mounting near the controlled door, or **ized mounting in the controller enclosure .
Features
Supports all popular card reader technologies Door contact signal input Request-to-exit signal input 2 auxiliary inputs Door lock / lock output (relay-driven) Auxiliary output (open collector) Card reader power supply Input signal line supervision Communication status LED Activity status LED Power status LED Upgradable flash memory Capability for remote maintenance, significantly reducing overall maintenance time Effective on-site management tool Host-system compatible, downloading hardware drivers and settings from the ACC
Through one reader, the SRI controls all electronic components of the protected door or barrier, including the entry reader, the request-to-exit device, the door closing and opening devices, and the door contact that monitors the door position. The SRI allows the inputs on the main board to be supervised individually. This greatly **s security: for example, if a tamper-protected input is detected as short-circuited, the system receives an alarm signal generated by the SRI. The SRI provides 2 programmable auxiliary inputs to monitor various aspects of the system. These can include monitoring the enclosure door, a duress switch, or a PIR motion detector. The SRI also provides an open-collector auxiliary output, allowing connection of a buzzer, alarm lamp or other devices. The user can set these devices to be triggered when the security system is breached. Using the ** flash memory technology, the SRI is fully upgradable and easy to program from the host to run in the desired mode. This leading-edge technology allows the SRI to be reprogrammed and reconfigured and used together with Siemens¡¯ other security products, giving the user a ** and fully scalable access control solution.
Electrical Voltage (Input) 12VDC +/- 20% Power 12W (full load) Card reader formats supported by the single reader • Barcode • Magnetic stripe • Wiegand Electric lock Relay-driven 10A@30VDC/2**VAC Auxiliary output 12VDC open collector (max. **mA) Inputs Door contact Request to exit 2 auxiliary points (passive devices only) Communication port RS-485£¨half-duplex£© Supervision Requires connection to a supervision circuit
Siemens Access Control - SRI Single Reader Module Shanghai Zitin Exclusive Store +86 21 68568185 www.zitin.com/siemens
|
|
|