| Product Catalog |
 |
Access Control & All-in-One Card Systems |
 |
| |
|
 |
Automatic doors ¨C sensor doors- Revolving Door |
 |
| |
|
 |
Door hardware and partitions |
 |
| |
|
 |
Sensor doors - electric doors - glass doors - sliding doors |
 |
| |
|
| |
| Brand Recommendations |
| |
|
 |
| |
| Contact Phone |
| +86 21 68568185 68567085 |
| Beijing, Shanghai, Guangzhou, Shenzhen |
| Fax |
| +86 21 68567085 |
|
|
| Product Inquiry Technical Service |
 |
| Automatic door repair & sensor door maintenance in Shanghai - official website www.zitin.com.cn www.shanghai-door.com |
| DORMA automatic doors, door closers, floor springs - www.zitin.com.cn/dorma DORMA sensor door repair & maintenance official website www.shanghai-door.com/dorma |
| GEZE automatic doors, door closers, floor springs: www.zitin.com.cn/geze official website for GEZE sensor door repair & maintenance: www.shanghai-door.com/geze |
| Hangzhou, Suzhou, Nanjing, Chengdu, Chongqing, Wuhan, Xi'an, Tianjin, Changsha, Foshan, Xiamen, Fuzhou |
| Zhengzhou, Dongguan, Qingdao, Jinan, Shenyang, Kunming, Ningbo, Wuxi, Changzhou, Hefei, Dalian |
| Service center for the design, installation, repair, maintenance and upkeep of Shanghai sensor doors, electric doors, glass doors and sliding doors. Products are used in shopping malls, supermarkets, banks, shops, retail stores, automotive facilities, hospitals, office towers, residential communities, data centers, factories and more. |
 |
|
|
Current location: Home>Products > Access Control & All-in-One Card Systems > Access Control & Attendance Systems >
SIEMENS Access Control -DRI Dual Card Reader Module |
Beijing, Shanghai, Guangzhou, Shenzhen, Hangzhou, Suzhou, Nanjing, Chengdu, Chongqing, Wuhan, Xi'an, Tianjin, Changsha, Foshan, Xiamen, Fuzhou, Zhengzhou, Dongguan, Qingdao, Jinan, Shenyang, Kunming, Ningbo, Wuxi, Changzhou, Hefei, Dalian Price |
SIEMENS Access Control -DRI Dual Card Reader Module |
SIEMENS Access Control -DRI Dual Card Reader ModuleInstallation manual, video, repair and maintenance service center prices |
| |
|
|
|
Siemens Access Control - DRI Dual Reader Module Shanghai Zitin Exclusive Store +86 21 68568185 www.zitin.com/siemens
SiPass Integrated Dual Reader Interface (DRI)
Securing doors is the main responsibility of any good access control system. The field-level devices that provide the interface between the system and the door¡¯s security components must be reliable, flexible and easy to install.
The Dual Reader Interface (DRI) offers all of these qualities. The DRI provides a local interface between the Advanced Central Controller (ACC) and the two readers installed beside each door ¡ª one for entry and one for exit. Thus, when a cardholder requests entry to or exit from a locked door, the DRI receives the cardholder¡¯s identity information and then sends that identification data to the ACC for processing.
In addition, the DRI is intelligent enough to report the door¡¯s status and, on command, unlock or lock the door. When a cardholder presents the access card to the entry or exit reader (connected to the DRI), the DRI interprets the encoded information and sends this data to the ACC. The ACC then checks the validity of the cardholder¡¯s identity. If the cardholder has been granted the appropriate permission, the ACC sends a message back to the DRI, allowing it to unlock the door and provide passage.
Carefully engineered, the DRI can be installed at any suitable location. The user can conveniently mount it near the controlled door or simply install it in the controller enclosure.
Features
Supports all common card reading technologies Supports one entry and one exit reader Door contact (entry) input Request-to-exit input 3 auxiliary inputs Supports supervised and unsupervised input devices Door lock / lock strike output (relay-driven) Auxiliary output (relay-driven) Card reader power supply (shared by two readers) Auxiliary 12Vdc power supply Input cable supervision Communication status indicator (LED) Operating status indicator (LED) Power status indicator (LED) Backup battery with deep-discharge protection Upgradable flash memory Supports remote maintenance Significantly reduces maintenance time Host-compatible; firmware and configuration parameters downloadable via the ACC
Product Specifications
|
Power Supply (Input) |
|
Power Supply (Input) |
12-32Vdc¡À20%(without a backup battery below 14Vdc) |
|
Power Consumption |
25W(at full load) |
|
Interfaces |
|
COMPort |
RS-485£¨half-duplex£© |
|
Reader Interface |
2 interfaces, supporting the following formats:- Barcode- Magnetic stripe- Wiegand |
|
Integrated Communication |
RS-485(Up to 16 local devices per FLN) |
|
Diagnostics |
RS-232(Transmit, Receive, Ground) for downloading firmware, RU-12 |
|
Integrated Communication |
OptionalRS-232/RS-485/RS-422Port |
|
Supervision |
Requires connection to a supervision circuit |
|
Backup battery |
12Vdc 4-7.**h(not provided) |
|
Inputs |
|
|
Door contact (entry), request to exit, 3 auxiliary inputs |
|
|
|
|
Outputs |
|
Door lock output |
Relay-driven 10A@30Vdc Resistive2**Vac Inductive |
|
Auxiliary output |
Relay-driven 10A@30Vdc Resistive2**Vac Inductive |
|
Mechanical/Physical Specifications |
|
Dimensions |
125mm X 125mm X 36mm (4.92in (W)X 4.92in (L)X1.42in (H)) Bare dimensions |
|
Enclosure |
RecommendedIP55£¨NEMA2£© |
|
Environmental |
|
Temperature |
Operating temperature: 10¡æ to **¡æ£¨**¡ãF to 122¡ãF) Storage temperature: 0¡æ to 60¡æ£¨32¡ãF to 140¡ãF£© |
|
Humidity |
10% to 90% relative humidity, non-condensing |
|
Service Life |
35¡æ£¨95¡ãF ) at this temperature, 60,000hours |
|
Indicators |
|
Power |
Indicates power is on |
|
Operating status |
Indicates the microprocessor is running |
|
Communication |
Indicates communication in progress |
Siemens Access Control - DRI Dual Reader Module Shanghai Zitin Exclusive Store +86 21 68568185 www.zitin.com/siemens |
|
|