Panasonic Automatic Door Commissioning Method
I. Direction commissioning methods for Panasonic automatic doors:
1. Commissioning method for the Panasonic automatic door belt fixing device.
2. Commissioning method for Panasonic automatic door handle parameter changes.
Note: the above methods can all achieve automatic door commissioning; the first method applies to commissioning automatic doors of both ** and ** brands. Method 2 can be used in special cases and requires ** equipment.
Next, what to do if the Panasonic automatic door direction is reversed? How to judge whether the direction is normal?
1. During installation and commissioning, after power-on, the automatic door slides closed and then automatically opens — this can be regarded as reversed direction, but it does not close again.
2. When the automatic door is open, pressing the reset switch to close the door leaf can be regarded as a direction fault.
3. When the automatic door is in sensing mode, it does not respond; when a person walks out of the sensing range, the automatic door opens — this can be regarded as reversed direction.
III. Specific operation method for Panasonic automatic door direction commissioning:
1. Commissioning method for the automatic door belt fixing device.
Method: change the order of the upper and lower belt seats to change the direction; note the distinction between upper and lower belt seats. Diagram of the normal direction for double sliding automatic doors: double-opening normal direction. Diagram of the normal direction for single-leaf automatic doors: single-opening normal mode.
2. Panasonic automatic door handle parameter commissioning method.
Method: use the Panasonic automatic door universal adjustment handle to adjust the direction parameter; the factory initial value is r
Specific operation flow:
1. Cut off the power and connect the Panasonic automatic door adjustment handle (note: mind the direction when plugging and unplugging; do not operate forcefully).
2. Manually close the automatic door and connect the power. Start the simulation action (open and close once slowly).
3. Following the above action, measure the doorway width; the handle's main display shows [Door]; take this as the standard display state.
4. Please refer to (the setting item list). Press the up/down keys to select parameter 3, then choose the appropriate value according to the actual scenario. Press set once to complete the setting.
5. Press the lock key to enter the standard state. Main display [Door].
After operation is complete, carry out a test.
Setting item list:
Setting No. / Function description / Setting range / Factory initial value / Unit. 2 — door opening direction when opening the door; set the direction (right)/left and double door to right.